Wired Touchpanels Crestron Series 1600
Appendix B: Cutout Detail of Supplied Template
Use the alphanumeric codes in the illustration and table to obtain the cutout
dimensions for the lectern/wall mount models when mounting without the BB-1600.
However, Crestron recommends that the supplied template be used to avoid error.
UNIT CUTOUT
CRESTRON
VERTICAL MEASUREMENTS HORIZONTAL MEASUREMENTS
V1 = 5.041 in (12.804 cm) H1 = 0.663 in (1.684 cm)
V2 = 0.089 in (0.226 cm) H2 = 2.318 in (5.888 cm)
V3 = 5.681 in (14.430 cm) H3 = 1.200 in (3.048 cm)
V4 = 5.502 in (13.975 cm) H4 = 3.835 in (9.741 cm)
V5 = 0.330 in (0.838 cm) H5 = 5.835 in (14.821 cm)
V6 = 5.638 in (14.321 cm) H6 = 7.161 in (18.189 cm)