Crestron CHV-TSTATEX Guide d'installation Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 92
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Operations and Installation Guide DOC. 8163E Thermostats: CHV-TSTAT and CHV-THSTAT
27
Heat/Cool, 1 or 2 Stages, Forced Air or Radiant
Press and hold the MODE and VIEW buttons simultaneously for 5 seconds to enter setup.
SETUP: SYSTEM
SETUP: SYSTEM
Heat Sys Type:
# Heat Stages:
# Cool Stages:
Radiant / F. Air:
H/C
2
2
F.Air
SEPARATE HEAT AND COOL
Press To Continue
Heat Sys Type: H/C
# Heat Stages: One or two heat stages.
# Cool Stages: One or two cool stages.
Radiat /F. Air: Radiant or Forced Air Heat.
SETUP: SYSTEM PERFORMANCE
SETUP: SYSTEM PERF
Heat Anticipator:
Cool Anticipator:
Intrstg Differential:
5
2
2.0
0
ADJUSTS HEAT SHUTOFF DYNAMICS
SETUP: SYSTEM PERF
ACCUMULATED ERROR THRESHOLD
TO TRIGGER 2ND/AUX STAGE
1=SMALL TIME,5=LARGE TIME
6=DEFEAT ACCUMULATED STAGING
Staging Accum Thresh 4
Press To Continue
Heat Anticipator and Cool Anticipator: Select 16.
Low number = more frequent cycles, faster response.
High number = less frequent cycles, slower response.
NOTE: A setting of 3 is recommended for most
installations.
Intrstg Differential: Select 0.5º8.0º F.
The proportional temperature error to trigger the second
stage.
Staging Accum Thresh: Select 16.
The feature optimizes triggering of the second stage to meet
demand in instances where the first stage cannot reach the
interstage differential or achieve the desired setpoint.
Low number = more aggressive trigger for second stage.
High number = less aggressive trigger for second stage (6
disables this feature altogether).
NOTE: A setting of 3 is recommended for most
installations.