FlipTop Data Center Crestron QM-FTDC
gauge used in interconnecting cables. The ratings on the connecting unit's supply
input should be considered to prevent overloading the wiring.
Attach the optional labels (included) to the pass-through telecommunication
connectors 1, 2 and 3.
1
2
3
Ground Wire Connections
Proper grounding is required. Connect the ground from the QM transmitter
(QM-FTDC) to earth ground. Connect the Cresnet shield at the QM-RMCRX-BA to
the chassis ground provided on the QM-RMCRX-BA. The QM-RMCRX-BA chassis
must also be connected to an earth ground (building steel). Refer to the following
grounding diagram.
Ground Wire Connections
NOTE: Do not connect the shield to earth ground at the QM-FTDC.
24 FlipTop Data Center: QM-FTDC Operations & Installation Guide – DOC. 6312B