Crestron e-Schedule Programmer’s Guide
Database Configuration
Except where noted, all of the tables detailed in this section are located in the
Microsoft Access database, Scheduler_Configuration.mdb. The examples
appearing in this section correlate with the Sample System on page 31.
Scheduling Software Computer(s)
The following two tables define the Web Server and Real-Time Engine
computer(s).
Cfg_Hardware_ServerMachine
Field Name Description
ServerMachineId The ID number of the Web Server
computer—must be “1”, as e-Schedule does
not currently support multiple Web Servers.
ServerMachineIPAddress The static IP Address of the Web Server
computer.
Cfg_Hardware_RealTimeMachine
Field Name Description
RealTimeMachineId The ID number of the Real-Time Engine
computer—must be “1”, as e-Schedule does
not currently support multiple instances of
the Real-Time Engine application.
RealTimeMachineIPAddress The static IP Address of the Real-Time
Engine computer.
Example 1 – Configuration tables for two e-Schedule computers. (Alternatively, the
Web Server and Real-Time Engine can be located on the same computer, in which
case the IP Addresses would be the same.)
WebServer/
CNX Gateway
Real-Time
Engine
Programmer’s Guide e-Schedule – DOC. 5919 9