Crestron C2N-IVDS24x24 Intercom Video Distribution System
Wire Gauge Values
RESISTANCE (R) WIRE GAUGE
4
16
6
18
10
20
15
22
13
Doubled CAT5
8.7
Tripled CAT5
NOTE: All network wiring must consist of two twisted pairs. One twisted pair is
the +24V conductor and the GND conductor. The other twisted pair is the Y and Z
conductors.
NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector and tighten the retaining
screw. Repeat the procedure for the other three conductors.
NOTE: For larger networks (i.e., greater than 28 network devices), it may become
necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality
throughout the network. Also, for networks with lengthy cable runs, it may be
necessary to add a Hub/Repeater after only 20 devices.
Identity Code
Every equipment and user interface within the network requires a unique identity
code (Net ID). These codes are two-digit hexadecimal numbers from 03 to FE. The
Net ID of each unit must match an ID code specified in the SIMPL Windows
program. Refer to “Setting the Net ID in Device Settings” on page 16 for details of
the SIMPL Windows procedure.
Refer to the note on page 20 for a
definition of Viewport.
The Net ID of the IVDS has been factory set to 45. The Net IDs of multiple IVDSs
in the same system must be unique. Net IDs are changed from a personal computer
(PC) via the Crestron Viewport.
NOTE: For detailed information on establishing communication between the PC and
control system, refer to “Communication Settings” on page 20. If communication
cannot be established, refer to the “Troubleshooting Communications” section in the
respective Operations Guide for the control system.
There are two different methods—Method A or Method B—for setting the Net ID:
Method A (Cresnet address-settable ID), described on the following page, applies to
devices in a Cresnet system with a CNX control system or with a 2-Series control
system and requires that a single unit be the only network device connected to the
control system.
Method B (Touch Settable ID or TSID), which begins on page 10, applies to all
TSID-ready devices in a Cresnet system with 2-Series control system upgrade file
(CUZ) version 3.029 or later. TSID functionality makes it possible for the control
system to recognize a network device via its serial number, which is stored in the
device’s memory. This method does not require that any devices be disconnected
Operations Guide - DOC. 6171 Intercom Video Distribution System: C2N-IVDS24x24 9
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 31 32

Commentaires sur ces manuels

Pas de commentaire