IP Considerations Guide for the IT Professional
6
Doc. 4579D
|
crestron.com
Listen Ports
On the Control Subnet, the number of listen ports on the LAN changes. There are an additional 100 listen ports.
Crestron utilizes listen ports 64,000 to 64,099 as the range which can be changed. Listen ports are used for
Crestron configuration changes for Crestron devices on the Control Subnet and dynamically open and close.
Control Subnet Example
IP Addressing
Automatic Mode (Default)
In order to eliminate routing conflicts between the Control Subnet and the LAN, the Control Subnet IP address is
automatically set based on the LAN-side Ethernet configuration. Refer to the table below for more information on
Control Subnet IP addressing in automatic mode.
LAN Control Subnet
Class A Class B (172.22.0.0/16)
Class B Class A (10.0.0.0/8)
Class C Class B (172.22.0.0/16)
Manual Mode
There is usually no need to change the Automatic Settings and there is no conflict. If necessary, the user can set
the routing prefix for the Control Subnet manually. This should only be done if the LAN contains a network that
conflicts with the Control Subnet.
NOTE: If the routing prefix is set on the Control Subnet any reserved leases are erased and the control system no
longer checks for routing conflicts between the LAN and the control system. It is important that the user is familiar
with this procedure before proceeding.