Crestron IM-FTCC-B iMedia FlipTop Computer Center
Mounting Brackets Installed - IM-FTCC-B
FOUR #10-32 2"L
SCREWS
6.77 in
(17.20 cm)
EIGHT
#6-32 3/16"L
SCREWS
TWO MOUNTING BRACKETS
Mounting Brackets Installed - IMI-FTCC-B
7.34 in
(18.64 cm)
FOUR #10-32 2"L SCREWS
TWO MOUNTING BRACKETS
EIGHT #6-32 3/16" L SCREWS
Hardware Hookup
Refer to the following hookup diagram and, aside from attaching power last,
complete the connections in any order.
NOTE: To prevent overheating, do not operate this product in an area that
exceeds the environmental temperature range listed in the specifications table.
Consideration must be given if installed in a closed or multi-unit rack assembly,
inside a closed desk, or in a closed podium since the operating ambient
temperature of these environments may be greater than the room ambient.
Contact with thermal insulating materials should be avoided on all sides of the
unit.
NOTE: The maximum continuous current from equipment under any external
load conditions shall not exceed a current limit that is suitable for the minimum
wire gauge used in interconnecting cables. The ratings on the connecting unit's
supply input should be considered to prevent overloading the wiring.
Operations & Installation Guide – DOC. 6349A iMedia FlipTop Computer Center: IM-FTCC-B • 17