Ethernet Input/Output Module Crestron CEN-IO ERR (Ethernet) This LED illuminates when an Ethernet protocol error is detected. RELAY (1 - 8) These LE

Page 3 - Contents

Crestron CEN-IO Ethernet Input/Output Module Hookup Connections for CEN-IO NOTE:CABLES ARE NOT SUPPLIED.ETHERNET CONNECTION NOT SHOWN.PCPOWER PACK(50

Page 4

Ethernet Input/Output Module Crestron CEN-IO Apply power to the CEN-IO and notice that the MAIN MENU is displayed in the Viewport window, shown below

Page 5 - Description

Crestron CEN-IO Ethernet Input/Output Module TCP/IP Configuration Depressing “1” from the NETWORK FUNCTIONS MENU opens the TCP/IP CONFIGURATION MENU

Page 6

Ethernet Input/Output Module Crestron CEN-IO SNMP Configuration Depressing “2” from the NETWORK FUNCTIONS MENU opens the SNMP CONFIGURATION MENU whic

Page 7 - Physical Description

Crestron CEN-IO Ethernet Input/Output Module Configure Community Strings Depressing “2” from the SNMP CONFIGURATION MENU opens the CONFIGURE COMMUNIT

Page 8 - CEN-IO Ports

Ethernet Input/Output Module Crestron CEN-IO (254 character maximum) and depress ENTER. The program responds with a ‘SAVED’ message and prompts the u

Page 9 - CEN-IO Indicators

Crestron CEN-IO Ethernet Input/Output Module master CRESNET ID and prompts the user to ‘Enter the entry number to remove’. Enter the entry number (1,

Page 10 - Preparation for Use

Ethernet Input/Output Module Crestron CEN-IO the numbers consecutively. When all the numbers are entered, depress ‘9’ to return to the RELAY SELECTIO

Page 11 - Setup Menus

Crestron CEN-IO Ethernet Input/Output Module Restart Box Depressing “6” from the MAIN MENU allows the user to restart the device. The program respond

Page 13 - TCP/IP Configuration

Ethernet Input/Output Module Crestron CEN-IO Block Diagram of System Incorporating a CEN-IO The touchpanel has an ON and OFF button for each zone (j

Page 14 - SNMP Configuration

Crestron CEN-IO Ethernet Input/Output Module System View of the CT-3500 in SIMPL Windows’ Configuration Manager System View of the CEN-IO in SIMPL W

Page 15

Ethernet Input/Output Module Crestron CEN-IO Expand the Ethernet folder and double click on the CEN-IO for a detail view (alternatively CTRL+D or dra

Page 16 - Manipulate Master List

Crestron CEN-IO Ethernet Input/Output Module Detail View of the ANALOG INITIALIZE (S-1 and S2) in SIMPL Windows’ Programming Manager NOTE: For a m

Page 17 - Relay Control

Ethernet Input/Output Module Crestron CEN-IO Detail View of the OR (S-4.2 and S-5.2) in SIMPL Windows’ Programming Manager Problem Solving Troubles

Page 18 - VersiPort Control

Crestron CEN-IO Ethernet Input/Output Module Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for

Page 20 - How to Create the Program

Crestron CEN-IO Ethernet Input/Output Module Appendix CEN-IO Management Information Block (MIB) The Management Information Block file, cenio.mib, def

Page 21 - Programming Manager

Ethernet Input/Output Module Crestron CEN-IO relay OBJECT IDENTIFIER ::= { crestron-CENIO 1 } versiport OBJECT IDENTIFIER ::= { crestron-CENIO 2 }

Page 22

Crestron CEN-IO Ethernet Input/Output Module relayDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mand

Page 23

Crestron CEN-IO Ethernet Input/Output Module Contents Ethernet Input/Output Module: CEN-IO 1 Description...

Page 24 - Problem Solving

Ethernet Input/Output Module Crestron CEN-IO DisplayString, versiportDigitalInput INTEGER, versiportAnalogInp

Page 25 - Return and Warranty Policies

Crestron CEN-IO Ethernet Input/Output Module ::= { versiportEntry 5 } versiportGroundingState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write

Page 27 - Appendix

Crestron CEN-IO Ethernet Input/Output Module Glossary of Terms Community String Community strings are passwords that let an SNMP controlled device kn

Page 28

Ethernet Input/Output Module Crestron CEN-IO Master List Master list is a list of Crestron Internet Protocol (CIP) enabled devices that will be infor

Page 29

Crestron CEN-IO Ethernet Input/Output Module Operations Guide - DOC. 5718 Glossary of Terms • 31 This page intentionall

Page 32

Crestron CEN-IO Ethernet Input/Output Module Ethernet Input/Output Module: CEN-IO Description Functional Description The CEN-IO is an Ethernet interf

Page 33 - Glossary of Terms

Ethernet Input/Output Module Crestron CEN-IO Digital Outputs: <01> through <08> When a logic high signal is placed on <o1> through

Page 34

Crestron CEN-IO Ethernet Input/Output Module Example: A voltage source is placed on versiport 1. <MinChange1> is set to 10 via an Analog Init

Page 35

Ethernet Input/Output Module Crestron CEN-IO CEN-IO Physical Views INPUT/OUTPUTRELAY OUTPUT CEN-IO Ports Most ports are provided on the back of the C

Page 36

Crestron CEN-IO Ethernet Input/Output Module I/O (1 - 8, G) This 9-pin connector (eight input/outputs and one common) is used to detect digital and a